...instrukcja serwisowa w pełni czytelna i kompletna. Dziękuję!
Tekstowy podgląd strony 16 (kliknij aby zobaczyć)
2. Protect mode
(1) Symptom
1) After lighting once it does not discharge minutely from the module. 2) The relay falls.(there is an audible �Click�.) 3) The color of the front LED turns from green to red.
(2) Follow check
Start Check
Is the Power Board normal ?
No
Is the output the normal Low/High voltage except for the Stand-by 5V?
No
Replace Power Board.
Yes No Are all the connectors normal? Yes No Is the appropriate fuse (FS2,FS3) on the Y-B/D? Yes Yes Replace the fuse. No Is the output voltage normal after removing the P1 connector of the Y-B/D? No Replace the connector.
After checking each connector does is operate correctly?
Is the Y-Board normal?
Replace the Y-Board.
Is the Z-Board normal? Yes
No
Is appropriate fuse (FS1,FS2) on the Z-B/D? Yes
No
Is the output voltage normal after removing the P1 connector of the Z-B/D?
Replace the Z-Board.
Replace the fuse.
No Is the X- Board normal?
Is the output voltage normal after removing the P100, 110, 200, 210 connector of the X-B/D?
After removing the P100, 110 and the output voltage is normal : Replace the Right X-B/D After removing the P200, 210 and the output voltage is normal : Replace the Left X-B/D